Model
TR-TLC2000
Description
Central coordinate controller modularity international communication protocol hand-heldterminal Max. 112 output meet the standard of GB2528-2010 Road Way Traffic Coordinate Controller
Interface
Laptop/mobile phone/pad
Overview
Central coordinate controller TR-TLC2000 adopts hardware modular design concept with cordwood system for expension. Software platform uses the embedded Linux operation system which is stable and reliable. Build-in induction and half induction control algorithm greatly improve the traffic capacity at intersections. Annunciator follows follows the standard GB2528-2010 Road Traffic Signal Control Machine. The communication protocol between PC and annunciator follows the standards of GB/T 20999-2007 communication protocol between traffic signal control machine and PC, which can be compatible with other systems using the same standard. It is good for system integration and extension. The communication protocol between annunciator and countdown counter follows GA/T 508-2004 Road Traffic Signal Countdown Display which can communicatewith the countdown counter having the same protocol.
Main Functions
Coordinated control together with command center by networking (control in line or lay)
Lineless coordination control
Multi-time control
Sensor conrol
Manual phase stepping control
Pedestrian crossing trigger control
On-board wireless special control
Holding wire/wireless control
Traffic parameter acquisition
Fault detection and alarm
Fault degraded running
Yellow flash for hardware failure
Overvoltage protectioin
Input & Output Interface
Signal light output: 56, expandable to 112, SCR output, single drive capability, AC220V/3A;
Vehicle detection input: 36, dry contact or OC transistor output;
Communication interface: Standard EIA
Level RS232 interface: 3, baud rate: 1200bps—115200 bps
RS485 level signal interface: 1, for countdown counter communiation
Network interface: 1, 10M/100M self-adaption
GPS interface: 1, can reeive GPS time service (optional)
Pedestrian request interface: 2, dry contact signal
Characteristic Parameter
Numbers of pre-setable time base dispatch table: 40
Numbers of pre-setable time table: 16, numbers of pre-setable times in each time table: 48
Numbers of pre-setable plans: 32
Numbers of pre-setable section table: 16, numbers of pre-setable times in each time table: 16
Numbers of pre-setable phase: 24
Max. time of red, yellow, green light: 225s
Fault Detection
Green conflict fault detection
Fault of all red light extinguishing in one signal light group
Fault of red light and green light set on at the same time in one group
Detection of light working voltage and working current
Detection of communication fault
Mechanical Property
Dimession:1280×600×440mm(H×W×D)
Weight:40kg
Enclosure protection class:IP54
Electrical Performance
Voltage: Single phase AC220V±20% 50Hz
No-load power consumption: 20W
Insulation resistance between AC input end and box is more than 10MΩ
Environment Index
Working condition:-20℃--+70℃
Storage condition:-40℃--+80℃
Humidity:5%--95%,40℃ non-condesing
Impact:10g/16ms,half sinusoid ,100 times
Vibration:5-33Hz,1g/1h, tow-ways: 2.5m
Reliability
MTBF>10000hr.
Maintenance
MTTR≤0.5hr.
Installation
Floor type
Installation Dimenssion
Accesories
User Manual×1
Key 6
Protectve tube×5
Tagboar×1
Certification×1
-
-